Questions & Answers

For Ge Microwave Fuse (Part Number: OEM11982195)

1 Answer

Hello Jim. No, you must order and replace the board to repair the bad display on the unit.

Read More...

1 Answer

Hello Harry. Disconnect the power and remove the outer cover from the unit. Next access the filter power board WB27X10519. Now pull out the old fuse on the board and press the new fuse into the holder on the board.

Read More...

1 Answer

Vincent, Unfortunately we do not have any information on this fan. Please refer to the owners manual for the number to the manufacturer to resolve issue.

Read More...

1 Answer

Sophia, Microwaves that don't heat and have a loud hum noise usually indicates and issue in the high side components, and usually a faulty diode WB27X35382 or magnetron WB27X10927. These are hi voltage components and you have to be careful when you're dealing or working with them. To access and test them you'll need to remove the machine from the cabinet and remove the outer cabinet casing.

Read More...

1 Answer

Gary, There are a couple of fuses on unit. There is a 20 amp 250 v fuse that is behind the control panel that you could test to see if it is bad. There are also thermal cutoff fuses inside the unit. To access the 20 amp fuse you will remove the grill and take screw out at top of control panel and take off the control panel. The other fuses would require the unit to be pulled from installation and take the cabinet off to test for continuity on the fuses to make sure that they are good. If there is no continuity then replace the fuse.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question