Need Help?
Call or text
Some parts shown may not be for your model. To see parts for your model only, select it from "Matching Model Numbers" list on the left.
The Dryer Gas Valve Coil Kit is an OEM replacement part for Whirlpool dryers, as well as Kenmore and Samsung dryers. It is a set of coils that control the flow of gas fuel to the burner. The gas valve regulates the precise amount of gas needed to properly combust and generate heat for drying clothes.
Causes of a bad gas valve coil can be wear and tear from regular use, lime or mineral buildup on the coils over time, or physical damage to the coils.
Symptoms of a bad gas valve coil kit include:
This OEM Whirlpool part can also be used on Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and Kenmore/Sears brand appliances.
I'm starting with a quick background on my dryer. About 18 months ago the belt on the dryer started slipping and squealing. I had a can of belt dressing spray so I popped the top open and sprayed the belt. It actually worked for about a year before it started squealing again. For the next 6 months I had to spray it more and more often. Then the clothes stopped drying. Obviously, at this point, I had to get off my lazy ass and fix the dryer. Searched my dryer's model number on the internet and... Read more
The Igniter Kit and Bracket is an OEM replacement part for Whirlpool dryers. It is a kit that includes the igniter and bracket assembly, which work together to ignite the gas or electric heating element.
Causes of a bad igniter and bracket can include failure due to prolonged or repeated use, damage from impact or mishandling, or failure of integrated electronic components.
Symptoms of a bad igniter and bracket include:
This Whirlpool replacement part is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and some Kenmore models.
I used Fixya as an initial source describing my problem. I got two responses which were very helpful. One that the "coils" were probably the problem. Two, that the problem could be the thermostat or a thermistor in the dryer. I verified that AC was coming from the timing control, that both the two terminal and three terminal coils,the igniter and shut off thermostat all had continuity. I then applied AC directly to the coils: the two terminal coil ""clanked" and I interpreted that as the coil... Read more
The Flame Sensor is an OEM replacement part for Whirlpool gas dryers. This component plays a critical safety role by monitoring the presence of the gas burner flame during the drying cycle.
Causes of needing to replace the flame sensor can include normal wear and tear over extended use, exposure to high temperatures or corrosion, or physical damage to the sensor itself.
Symptoms that may indicate a faulty flame sensor include:
This OEM part is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and Kenmore gas dryer models.
The Natural Gas Limiter is an OEM replacement part for Whirlpool dryers. Located where the gas supply connects, it regulates safe flow levels to fuel burners during heating cycles. Precise control prevents over-firing issues. Symptoms of a faulty limiter include:
Causes can range from debris accumulation reducing gas flow to mechanical wear of linkage components. This replacement restores optimized operation. This OEM replacement part is compatible with select KitchenAid and Maytag brand models.
Removed LP Orifice and LP Gas limiter. Orifice was easy, however the gas limiter was the tricky one because I had no instructions to what went where. I could not find anything online as to how to convert from LP to Natural Gas, but you could find several things as to how to convert from Natural to LP. I ended up finding the Dryer schematic on line for the Whirlpool Duet natural gas dryer and was able to figure out what sequence the Spring, regulator and limiter went in. The order I just... Read more
This screw is used to secure the handle end cap to the center of the door. The screw size measures 8-18 x 1/2 inches.
This was actually one of the easiest fixes I’ve done. All that was required was to remove 3 screws to remove the broken part. I used a pair of pliers to remove the moisture sensors from the broken part to the new one. Read more
The Natural Gas Orifice is an OEM replacement part for Whirlpool gas dryers. Installed within the dryer burner assembly, it regulates gas fuel flow into the burner. Common causes relate to natural deposits obstructing the small gas port, as well wear inducing intermittent ignition of flames during many years of laundering cycles. Symptoms of a failed orifice include:
This is a genuine Whirlpool OEM replacement this part is also compatible with Maytag, Jenn-Air and some Kenmore models.
Confirmed parts needed through online chat with tech and followed video instructions for dryer conversion. Found a video online for range conversion. Replaced orifices for stove top and adjusted oven burner orifices and air shutters and inverted pin in pressure regulator to natural gas position. All went well with no problems, about an hour and a half to gather tools and complete both jobs. Probably could be done faster but I was taking my time. Read more
The Natural Gas Spring is an OEM part for Whirlpool ranges. This part assists in regulating the flow and pressure of natural gas to the burners, ensuring consistent and safe operation. The spring helps maintain the correct pressure within the gas regulator, which is vital for efficient cooking performance.
Causes of a bad natural gas spring can include wear and tear from prolonged use, exposure to high temperatures, or contamination from particles within the gas line.
Symptoms of a bad natural gas spring include:
This OEM Whirlpool part is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper and some Kenmore models.
The Natural Gas Regulator is an OEM part for Whirlpool ranges. This regulates the pressure of natural gas entering the appliance, ensuring safe and efficient operation. It maintains a consistent gas flow to the burners and oven, allowing for precise temperature control and optimal cooking performance. Over time, the natural gas regulator can wear out or become damaged due to exposure to high temperatures, contaminants in the gas supply, or mechanical failures. Symptoms of a bad natural gas regulator include:
This burner tube channels the gas-air mixture to the burner and includes an adjustable air shutter to set proper combustion. Replacing a damaged assembly helps restore reliable ignition, stable flame, and consistent heating performance.
I removed the kick panel/door and confirmed there was no flame. Inspection with a flashlight revealed the igniter was damage - partly broken away. Using a 1/4" socket set I removed the burner assembly. Inspection showed the burner was rusted and the flame deflector had fallen off. I ordered both the "Dryer Igniter and Bracket" and a burner. They arrived in about three days. I had to attach the igniter to the bracket (one screw) and then the bracket to the burner (one screw). The only... Read more
This 8-18 x 5/8-inch screw secures appliance panels, brackets, and covers. Replacing a missing or stripped fastener restores a tight fit and helps prevent vibration or loosening where this exact size is specified.
I put all pieces that I ordered on the dryer and plugged it in. Read more
This replacement gas valve controls gas flow to the burner in a gas dryer, enabling safe ignition and consistent heat. When it fails, the burner may not light and loads can stay damp; replacing it restores proper drying performance.
I decided the problem was with the gas valve and I found the part on your web site. I ordered it and received the part in 3 days. I replaced the valve and the dryer works like new! This also gave me an opportunity to vacuum out the dust/lint that collects in and around the dryer. Read more
Specs: 10-16 x 1/2 inch.
After shopping for a new Whirlpool Thin Twin Stack, Found appliance parts pros online and decided to take it apart to see if repair was a possibility. APPro's online instructions were easy to follow, in a couple hours it was apart, and I placed the order. Reg ground took a week from NY, so the laundry piled up that week. The parts arrived on Monday morrning, by afternoon the machine was running like new! The cause was the belt tensioner pulley had frozen. Replaced it, drum wheels,snap... Read more
This LP gas conversion label identifies that the appliance has been converted for use with liquid propane. Applying it near the gas valve/regulator clearly communicates fuel type for safe service, troubleshooting, and future installation decisions.
I ordered the conversion kit and it was perfect. Read more
This precision-drilled burner orifice is sized for Type 4 butane applications. It meters gas to the burner so flames ignite reliably and burn cleanly when the appliance is configured for butane per the manufacturer's specifications. What it does:
This orifice is the small gas passage that controls burner fuel flow to create a proper flame for cooking. It restores correct gas metering so the burner lights and maintains a steady flame. What it does:
This valve assembly controls incoming water flow to the appliance, restoring correct fill and preventing overfill or no-fill conditions when the original valve fails. It's a direct-replacement style part for affected units. What it does: