Joe for Model Number PLHS267ZCB0

Freezer works fine. Fridge is warm and not cooling. I noticed the damper was not on when I felt toward the back of the unit. So decided to loosen some of the screws and upon doing so the damper kicked on but now it comes on intermittently or not at all unless I loosen the front screws underneath the thermostat dials. This seems to kick it back on but sometimes it needs a light tap to get it going. Is this actually a bad thermo sensor and has nothing to do with damper?

1 Answer

Hello Joe. No, it sounds like the damper is bad and will need to be replaced on the unit.

Read More...
Carol C. for Model Number FRSKF6CQ1

A while back we were having issues with our Frigidaire Model #FRS23KF6CQ1 the Refrigerator was staying turn warm, freezer worked fine. We ordered Part Number: AP5176342 and installed it now the refrigerator stays to cold. Even with the thermostat control turned down to "0" the refrigerator stays between 28 & 32 degrees. Items are freezing in the refrigerator. It's like we cannot control the temp in the refrigerator. The freezer section is still working fine as before. Any suggestions? Thanks

1 Answer

Carol, It sounds like you may have gotten some wires crossed or may have received a defective part with the freezer getting to 28 degrees with a new control box kit.

Read More...
Too Figidaire for Model Number PLHS267ZCB0

I have the typical Figidaire failure mode. Freezing of food on the fridge side, with no damper door movement except when I unplugged then re-plugged in the unit. The damper door would cycle once then stay fully open. Replaced the Control assembly. The fride side temperature control of new control unit had no effect. The damper motor only cycled the damper once, like the old one. The new control assembly uses only one connector on the damper motor, the original control used two connectors. Which connector should be used, the one closest or furthest to the motor? When I contacted the supplier, they sent me a second control box. The wiring to the fridge/freezer thermostats was reversed from the first new one! It didn't work either.Is there a schematic with color codes for the thermostats? I have a real issue with Figidaire quality control.

Tom for Model Number FRS26R4AW1

Freezer side fine, refrigerator side still warm. Initially found evaporator coils frozen over and evaporator fan cycling on and off. Defrosted coils, installed new Defrost Thermostat and Adaptive Defrost timer control board. Now damper seems to stay closed, but when I unplug unit, door opens and when plugged back in it cycles closed. Condenser, condenser fan and compressor working normal. evaporator fan now working fine and coils are defrosting as they should. What am I missing, seems to be a damper issue, but it has power and works when unit turned on and off? Thanks

1 Answer

Hello Tom. The damper will be closed until the freezer gets to the correct temp, then should open to cool the fresh food side. If not, the cold control may be bad in the unit.

Read More...

1 Answer

Hello Garry! No, the control box kit 5304482075 is not listed as being compatible with your model. You'll have to get the parts separate as the parts are not available as a kit. The damper is part number 241600902 and temp controls are part number 240383703 and 5304496561. Thanks.

Read More...

1 Answer

Hello Greg. If it was not used on the old part, you will not use it on this part. Just lay it inside the housing.

Read More...

1 Answer

Tim, With having the control box replaced, you will want to make sure that all connections are made firmly and if they check ok then it sounds like the defrost board in the kit may be faulty as this is what supplies power to the fan motor.

Read More...
Justin for Model Number GLRS267ZCW1

Hello, I just wanted to ask as I cant seem to get the right answer for my question, I have already replaced the air damper door and the fridge temp control, and still have freezing food in fridge section. Damper door closes on 0 and opens all the way on any other setting. If I have already bought half of the components in this kit, why coudn't i just replace the remaining component, the ADC board? Does it have any control over the damper position?

1 Answer

Hello Justin. They have changed the design of the damper and control box. It is best to replace the kit on the unit. The ADC does not control the damper in any way. Only the fresh food control.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store