Josh January 18, 2017 for Model Number FPHS2387KF4 Hi, refrigerator side is reading 18 but all the food and drinks freeze. Had a guy look, he said the dampener is fine. Any thoughts? He said maybe the main control board needs to be switched. The freezer side is working fine. Thanks
1 Answer Josh, First check that the doors are closing and sealing properly, then check the shelves, make sure the articles are not hanging over the edges, or against the wall. Then check to make sure the sensor and sensor box are not blocked by an article or the air is not being redirected away from the sensor. Dismount the box, and check for loose connections or corrosion on the connector pins. If all's OK then replace the control board. Read More...
Andy December 14, 2016 for Model Number fghs2365kf1 The power board clicked off and on and then the UI showed a CE SY error. I replaced the power board and the new board did nothing. I assumed a bad new board so tried another one and it too did nothing. Part # 5303918498
1 Answer Hello Andy. Check and make sure all your wiring is good. If so, you will need to replace the dispenser board 241973711 in the unit. Read More...
Mark October 28, 2016 for Model Number LGHS2667KP0 Had the message SY CE and replaced the Main power board and now getting a SY CF message. The wiring harness on the new board does not look like the old one. Any ideas?
1 Answer Hello Mark. You have to use the new harness and plug the old harness into the new harness. If the code continues, then replace the dispenser board on the unit. Read More...
Mario September 01, 2016 I bought the main board AP4695205 to replace a 242000406 but the fridge doesn't do anything. With the old card at least the lights turn on.
1 Answer Hello Mario. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
Joe July 30, 2016 for Model Number CGUB2642CP3 My display board is showing a code sy-cf , would that be the main control board? if so, how much should that board cost.
1 Answer Joe, Yes the SY CF is a communication error and would most likely be caused by a faulty main control board. Read More...
Claude K. July 21, 2016 for Model Number ffqe5000qw My dryer had stopped running so I hire a technician to diagnose the issue. He said the problem was the control board. I replaced the control board of my Frigidaire dryer with a new one (I checked so I know that the part number is correct). However, with the new control board my dryer won't even display anything or turn on (with the old control board in I could see the display even if the dryer wasn't working). Does a Frigidaire dryer control board come with the software installed so it works after installation or is there an additional step need to make the control board active? What do you guys think I'm might be doing wrong? Thanks, Claude
1 Answer Hello Claude. You need to make sure you ordered 137070890NH. If so, you may have gotten a bad part. Read More...
Therev June 24, 2016 for Model Number Frigidaire refrigerator model FGHB2844LFE serial 4A24913442 While filling up my cup with ice the unit stopped dispensing ice and lights went out. There's electricity at the socket but the unit is not running at all.
Roseau Boy May 04, 2016 for Model Number FGHS2644KF1 FRIGIDAIRE - Side-By-Side Refrigerator Model: FGHS2644KF1 | Serial No:4A949810721 Frigidaire fridge clicking sound The original refrigerator Control Board part No: 242000411 develop a fault the relay 12V dc 0569C1 - kept clicking on/off and then after 1 minute it switched off completely. • The display shows SY - CE error code. Ordered a replacement control board, this arrived with the additional cable to connect to the original refrigerator main harness. The replacement Part No: 242009011 looks the same as the original Part No: 242000411. Connected all cable as per diagram, the refrigerator now fails to start, there is no power to the display panel, the refrigerator internal light is not on. The refrigerator is completely dead when install Control Board Part No: 242009011 Replaced the starting solenoid and evaporator fan. Do you have any idea why the replacement control board will not work with this current refrigerator model?
1 Answer Communication errors, SY CF & SY CE, indicate that the Main Control Board and User Interface are not interacting accordingly. SY CE : Communication Error - Communication between User Interface and Main Control Board was established at last POR, but then lost while the unit was in operation. If the Main Control Board is not able to communicate with the User Interface, the Fresh Food lights will be off. If an incompatible replacement User Interface and Main Control Board are installed, 12VDC will be present at RED and BLK wires to User Interface but the unit will not operate. Remove left hinge cover and verify 12VDC between RED and BLK communication wires (cabinet side). If voltage is correct, verify continuity of WHT communication wire between the Main Control Board and User Interface. Also, verify there is no continuity between cabinet ground & WHT communication wire. If voltage is not correct, access the Main Control Board. Locate J9-A connector on Main Control Board and check for 12VDC between RED and BLK wires. If voltage is correct at Main Control Board, check for loose connections, backed out connector pins, or broken wire between the Main Control Board and User Interface. Repair wire, if possible, and retest. After you perform the above checks and verify the wiring, the user interface board 241973711 may be needed. Read More...
Angela April 27, 2016 for Model Number LGHS2655KP0 My digital readout on front of freezer door is reading high.Both reading are in the high 30 and 40 degrees.There is a clicking sound also.It will not cool freezer or refrigerator.Do I need a control board.
1 Answer Angela, With the unit making a clicking noise you will want to check the compressor to ensure that the noise is not coming from the relay on the compressor. If it is not then the control board would be the issue. Read More...
John L February 12, 2016 for Model Number LGHS2665KF0 While moving the refrigerator to the garage and powering it up the unit starts with lights in freezer and refrigerator on. However, the temperature display did not light up. Thinking that I might have a connection to main board loose, I looked and noticed the J9 A1 terminals connection disconnected and that actually a pin was broken. So, I ordered a new board (AP4695205) and plugged it in. The unit clicked and did nothing else. Just to be sure nothing else was wrong I plugged the old board in and it was the same as before, i.e,, everything worked except the temperature display. Thinking that I might I have a bad board I contacted you guys and was sent a replacement. When I plugged in it was same as before, nothing. Once again I plugged the old board back in and everything works except the temperature display. Any suggestions? By the way, I also unplugged the J9 A1 connection on the new board to see if it would behave like the old board (i.e, works but no temperature display). It did not as it would the unit no power at all. Why isn't the new board behaving like the old board?
1 Answer John, In regards to this issue, there has been some problems with getting the correct board part number for your unit from the manufacturer. They recommend trying to connect with or without the harness that comes with the unit. If this still does not correct then try to contact the manufacturer to make sure that the correct board part number is being received for your unit. Read More...